This site is intended for healthcare professionals

Go to /sign-in page

You can view 5 more pages before signing in

Rule of threes

Authoring team

This rule dictates that no more than three successively larger dilators should be used above the size of the dilator that first meets resistance from an oesophageal stenosis.

It is more valid for metal dilators as opposed to stepped or balloon counterparts in which axial forces are lower.

The size of the initial dilator is often accurately assessed by examination of preliminary radiographs and at endoscopy.


Create an account to add page annotations

Annotations allow you to add information to this page that would be handy to have on hand during a consultation. E.g. a website or number. This information will always show when you visit this page.

The content herein is provided for informational purposes and does not replace the need to apply professional clinical judgement when diagnosing or treating any medical condition. A licensed medical practitioner should be consulted for diagnosis and treatment of any and all medical conditions.

Connect

Copyright 2024 Oxbridge Solutions Limited, a subsidiary of OmniaMed Communications Limited. All rights reserved. Any distribution or duplication of the information contained herein is strictly prohibited. Oxbridge Solutions receives funding from advertising but maintains editorial independence.