ECG changes in digoxin
Various ECG changes are associated with the use of digoxin:
ST depression and T wave inversion in V5-6 in a reversed tick pattern.
Changes are more extensive in digoxin toxicity.
Other changes that may occur:
- bradycardia
- prolonged PR
- shortened QT
- arrhythmias, especially heart block or bigemini